Troubleshooting - IV Arm
Problem
Veins do not energize.
Solution:
Ensure manikin is powered on and IV Arm cable and air tube are connected to the manikin.
Ensure the blood reservoir is filled, see Filling and priming the system.
Ensure the tourniquet area is activated (depressed).
Look for a leak between the IV Arm pad and the IV Arm chassis.
If the tourniquet area has been activated several times within a short period of time, internal pressure in the IV Arm may drop.
Wait 30 seconds to let pressure rebuild and try again.
Problem
When injecting more than 40ml fluid and prime switch is depressed, no fluid is visible in the drain tube.
Solution
Leak inside IV Arm. Contact Laerdal Technical Service.
Problem
After releasing the prime switch and filling the internal reservoir, more than 16ml of fluid can be injected into the arm.
Solution
Leak inside the IV Arm. Contact Laerdal Technical service
Problem
There is a leak between IV Arm Pad and IV Arm chassis.
Solution
Ensure the IV Arm Pad is fully inserted and secure in the IV Arm chassis.
If this does not help, too high pressure has been applied to the IV Arm Pad during the filling process. Replace the IV Arm Pad.
Problem
No flashback when inserting Intravenous Catheter into IV Arm Pad
Solution
Ensure that the collection bag is at the same elevation as the IV Arm.