9.2 THE MACHINE ATTEMPTS TO START UP BUT
IS NOT ABLE TO DO SO
• At low temperatures: The machine is too cold and must be
heated up to room temperature in a warm room.
• Cables which are too long or too thin are used for the
electrical connection:
- The power cables have a total length of more than 20 m
(790”).
- The power cables have wire cross-sections which are
smaller than 1.5 mm² (0.0023 sq.in.).
This causes of faults lead to a loss of power and are not
allowed for safety reasons!
• The electrical network is not providing sufficient voltage
(undervoltage). Use a transformer if necessary (e.g. LÄGLER
®
part number 708.00.00.100 for 230 V).
• The V-belt is too tight and must be loosened.
Section 7.2, Tightening the V-belt
9.3 THE MACHINE RUNS BUT HAS NO OR VERY
LITTLE SANDING POWER CAPACITY
• The sanding medium is incorrect or dull and must be replaced.
Section 5.2, Replacing the sanding medium
• At low temperatures: The machine is too cold and must be
heated up to room temperature in a warm room.
• Cables which are too long or too thin are used for the
electrical connection:
- The power cables have a total length of more than 20 m
(790”).
- The power cables have wire cross-sections which are
smaller than 1.5 mm² (0.0023 sq.in.).
This causes of faults lead to a loss of power and are not
allowed for safety reasons!
• The electrical network is not providing sufficient voltage
(undervoltage). Use a transformer if necessary (e.g. LÄGLER
®
part number 708.00.00.100 for 230 V).
• The V-belt is not tight enough and must be tightened a bit.
Section 7.2, Tightening the V-belt
• The machine setting angle is too flat. The guide rollers must
be properly adjusted.
Section 7.8, Adjusting the guide rollers