16: Maintenance and Diagnostics Settings
PremierWave® XC HSPA+ Intelligent Gateway User Guide 119
System Settings
The PremierWave XC HSPA+ intelligent gateway system settings allow for rebooting the device,
restoring factory defaults, uploading new firmware and updating a system’s short and long name.
Note: Anytime you reboot the unit, this operation will take some time to complete.
Please wait a minimum of 10-20 seconds after rebooting the unit before attempting to
make any subsequent connections.
Table 16-12 System Settings
To Reboot or Restore Factory Defaults
Using Web Manager
To access the area with options to reboot, restore to factory defaults, upload new firmware,
update the system name (long or short names) or to view the current configuration, click
System in the menu.
Using the CLI
To enter the command level: enable
Using XML
Include in your file: <configgroup name=”xml import control”>
System Settings Description
State
Click to enable or disable the reboot schedule.
Current date and time Displays the current date and time.
Schedule Select the Daily or Interval schedule from the drop-down menu.
Time (24 hour) Enter the Hour and Min (minute) in 24 hour time, for the reboot time if Daily
schedule is selected.
Interval Enter the interval number and select the interval type (Hours, Days, or
Weeks) from the drop-down menu.
Reboot Device
Click the Reboot button to reboot the device.
Restore Factory Defaults
Click Factory Defaults to restore the device to the original factory settings. All
configuration will be lost. The PremierWave XC HSPA+ intelligent gateway
unit automatically reboots upon setting back to the defaults.
Upload New Firmware
Write the new firmware file to firmware.rom on the PremierWave unit by
clicking Choose File to browse to the new firmware file, and click Upload
button to upload the chosen file to the system. The device automatically
reboots upon the installation of new firmware. See the section, FTP Settings
on page 86.
Short Name Enter a short name for the system name. A maximum of 32 characters are
allowed.
Long Name Enter a long name for the system name. A maximum of 64 characters are
allowed.
Submit (button) Click Submit after entering the system name.