EasyManua.ls Logo

Laser Technology UltraLyte - Survey Data Message Format

Laser Technology UltraLyte
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A
PPENDIX
A: S
ERIAL
I
NTERFACE
S
PECIFICATIONS
Electronic Copy of LTI’s UltraLyte User’s Manual – 7
th
Edition June 1998
66
$PLTIT,RQ,ID<CR>
[
<LF>
]
where:
$PLTIT
is the Criterion message identifier
RQ
indicates a request message
ID
indicates the request type
<CR>
[
<LF>
] is a carriage return and
optional linefeed.
The response returned by the instrument is in
the following format:
$PLTIT,ID,
model
,
versionid
*
csum
<CR><LF>
where:
$PLTIT,ID
identifies the message
model
indicates the UltraLyte model (UL100 or
UL200)
versionid
is the version ID of the internal firmware
*csum
is an asterisk followed by a hexadecimal
checksum. The checksum is calculated by
XORing all the characters between the
dollar sign and the asterisk.
<CR><LF>
is a carriage return/line feed combination,
which terminates each Criterion-format
message.
Example Version ID Messages
Request:
$PLTIT,RQ,ID
Response:
$PLTIT,ID,UL100,1.70*44
For Internal Use Only. Not for Distribution.