The measurement of accuracy is compliant with ISO 17123-8.
Type Horizontal Vertical
Static and rapid static 5 mm + 0.5 ppm 10 mm + 0.5 ppm
Kinematic
10 mm + 1 ppm 20 mm + 1 ppm
Static with long observations 3 mm + 0.5 ppm 6 mm + 0.5 ppm
Type Horizontal Vertical
Single Baseline (<30 km) 10
mm + 1 ppm
20 mm + 1 ppm
Network RTK 10
mm + 0.5 ppm
20 mm + 0.5 ppm
6.2.3 Technical Data
Type Height Diameter
GS07 0.071 m 0.186 m
8 pin LEMO-1
5/8" Whitworth
0.8 kg including internal battery
Type Description
Power consumption 2.0 W typically
External supply voltage Nominal 12 V DC (
), voltage range
10.5 V‑28 V
Type Battery Voltage Capacity
Operating time, typically
*
GEB212 Li-Ion 7.4 V 2.6 Ah 7 h
* The given operating times are valid for
•
one full
y charged GEB212 battery.
•
25°C. Operating times will be shorter when working in cold
weather.
Type GS07
Voltage -
Current -
Frequency
GPS L1 1575.42 MHz
ü
GPS L2 1227.60 MHz
ü
GPS L5 1176.45 MHz
ü
☞
Differential phase in
post-pr
ocessing
Differential phase in
real-time
Dim
ensions
Connector
Mounting
Weight
Power
Battery internal
Electrical data
52 Technical Data