EasyManua.ls Logo

Leica TS13 - Laser: Distance Measurement with Reflectors

Leica TS13
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
National laws and local regulations could impose more stringent
ins
tructions for the safe use of lasers than IEC 60825-1 (2014-05)
and IEC TR 60825-14 (2004-02).
1.6.2 Distancer, Measurements with Reflectors
The EDM module built into the product produces a visible laser beam which
emer
ges from the telescope objective.
The laser product described in this section is classified as laser class 1 in
ac
cordance with:
IE
C 60825-1 (2014-05): “Safety of laser products”
These products are safe under reasonably foreseeable conditions of operation
and ar
e not harmful to the eyes provided that the products are used and main-
tained in accordance with this User Manual.
Description Value
Wavelength 658 nm
Pulse duration 800 ps
Pulse repetition frequency (PRF) 100 MHz
Maximum average radiant power 0.33 mW
Beam divergance 1.5 mrad x 3 mrad
0016217_001
a
a Laser beam
1.6.3 Distancer, Measurements without Reflectors
The EDM module built into the product produces a visible laser beam which
emerges from the telescope objective.
The laser product described in this section is classified as laser class 3R in
ac
cordance with:
IE
C 60825-1 (2014-05): “Safety of laser products”
Direct intrabeam viewing may be hazardous (low eye hazard level), in particular
f
or deliberate ocular exposure. The beam may cause dazzle, flash-blindness
and after-images, particularly under low ambient light conditions. The risk of
injury for laser class 3R products is limited because of:
General
General
12 Safety Directions

Table of Contents