Pav = 4.8mW λ = 658nm tp = 800ps
IEC 60825-1:2014
Complies with FDA performance standards for laser products except for
deviations pursuant to Laser Notice No. 50, dated June 24, 2007.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
123456
S.No. :
123456
Art.No. :
Equip.No.: 1234567
Power: 12-15V 12W max
Leica Geosystems AG
CH-9435 Heerbrugg
Manufactured: 20XX
Made in Switzerland
TS13
Model:
0016219_001
1.6.5 Automatic Target Aiming ATR
The Automatic Target Aiming built into the product produces an invisible laser
b
eam which emerges from the telescope objective.
The laser product described in this section is classified as laser class 1 in
accordance with:
•
IE
C 60825-1 (2014-05): “Safety of laser products”
These products are safe under reasonably foreseeable conditions of operation
and ar
e not harmful to the eyes provided that the products are used and main-
tained in accordance with this User Manual.
Description Value
Wavelength 785 nm
Maximum radiant peak power per pulse 10 mW
Pulse duration £ 15 ms
Pulse repetition frequency (PRF) £ 213 Hz
Beam divergence 25 mrad