are corrected twice: first by the determined ATR errors for Hz and V, and then
b
y the individual small deviations of the current aiming.
IF the task is to THEN
adjust a combination of
ins
trument errors
Refer to "5.3 Combined Adjustment (l, t, i, c
and ATR)".
adjust the tilting axis Refer to "5.4 Tilting Axis Adjustment (a)".
adjust the circular level Refer to "5.5 Adjusting the Circular Level of
the Instrument and Tribrach".
adjust the laser/optical plum-
met
Refer to "5.7 Inspecting the Laser Plummet
of the Instrument".
adjust the tripod Refer to "5.8 Servicing the Tripod".
5.3 Combined Adjustment
(l, t, i, c an
d ATR)
The combined adjustment procedure determines the following instrument
er
rors in one process:
Instrument error Description
l, t Compensator longitudinal and transversal index
er
rors
i Vertical index error, related to the standing axis
c Horizontal collimation error, also called line of
sight error
ATR Hz ATR zero point error for horizontal angle option
ATR V ATR zero point error for vertical angle option
The following table explains the most common settings.
1. Leica Captivate - Home: Se
ttings\TS instrument\Check & adjust
2. Check & Adjust
Select the option: Check & adjust the compensator, index error,
line of sight error & automatic target aiming
3. Next
4. Face I measurement
Next step
Description
Combined adjustment
pr
ocedure step-by-
step
Check & Adjust 51