8.EnsurethatthethreeholesintheM.2storagemodulearealignedwiththethreeplasticpinsonthe
chassis.Then,lowertheM.2storagemodulestraightdownuntilitisseatedinplaceandsecuredby
theplastictabs.
Figure70.InstallingtheM.2storagemodule
9.ConnectthesignalcableofthenewM.2storagemoduletotheSATAconnectorontheAnyRAID
adapter.Then,connectthepowercabletotheM.2storage-modulepowerconnectoronthesystem
board.See“RAIDadapter”onpage32
and“Systemboardcomponents”onpage47.
Whattodonext:
•Toworkwithanotherpieceofhardware,gototheappropriatesection.
•Tocompletetheinstallation,goto“Completingthepartsreplacement”onpage180.
RemovingtheM.2storagemodule
Attention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Readthisfirst:safety
information”onpageiiiand“Guidelines”onpage69.
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanother
computerforreference.
Note:UseanydocumentationthatcomeswiththeM.2storagemoduleandfollowthoseinstructionsin
additiontotheinstructionsinthistopic.
ToremovetheM.2storagemodule,dothefollowing:
1.Removeallexternalmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,
disconnectallpowercordsfromelectricaloutletsanddisconnectallcablesthatareconnectedto
theserver.
2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaflat,
clean,andstatic-protectivesurface.SeetheRackInstallationInstructionsthatcomeswiththeserver.If
theserverisintowerformfactor,laytheserveronitssideforeasieroperation.
3.Removetheservercover.See“Removingtheservercover”onpage72.
116ThinkServerTD350UserGuideandHardwareMaintenanceManual