Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05 113
6 I/O terminals
6.2 Analog terminals
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Minimum and maximum output speed
The speed range required for the application results from the selected reference speed (C011
) and
the minimum analog setpoint (C010
):
• The reference speed set in C011
is reached at a speed setpoint selection of 100 %.
• All speed setpoint selections are provided in % and always refer to the reference speed set in
C011
(independent of the setpoint source).
•The speed set in C010
corresponds to the minimum speed if the speed setpoint has been selec-
ted via the analog input (Lenze setting) and a voltage of 0 V is applied to the X4/A1U input ter-
minal.
[6-1] Relation between the selected setpoint and minimum and maximum output speed
0 V
n
10 V
100 % = C00011
C00010