11 Function library
11.16 LS_SetError_1
332
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.16 LS_SetError_1
This system block is used for error handling within the application.
The application can trip up to two different user error messages with parameterisable error re-
sponse via the two boolean inputs.
If both inputs are set to TRUE at the same time, the bSetError1 inputs trips the error message.
Inputs
Parameter
Identifier
Data type
Information/possible settings
bSetError1
BOOL
Input for tripping "US01: User error 1"
Error subject number: 980
•Error number: (C581/1
x 0x0400000) + (980 x 0x10000)
bSetError2
BOOL
Input for tripping "US02: User error 2"
Error subject number: 981
•Error number: (C581/2
x 0x0400000) + (981 x 0x10000)
Parameter Possible settings Info
C581/1...2
Response for user error 1 ... 2
lenze setting: "Fault"
0 No response
1 Fault (pulse inhibit)
2Trouble
4 WarningLocked
/6B6HW(UURUB


E6HW(UURU
E6HW(UURU
5HDFWLRQ&
5HDFWLRQ&