10.2 Parameter list | C00574
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00574
C00581
C00592
Parameter | Name:
C00574 | Resp. to brake resist. overtemp.
Data type: UNSIGNED_8
Index: 24001
d
= 5DC1
h
Response when the permanently set threshold for monitoring the brake resistor utilisation has been reached.
Selection list (Lenze setting printed in bold)
0No Reaction
1Fault
4 WarningLocked
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00581 | Resp. to LS_SetError_x
Data type: UNSIGNED_8
Index: 23994
d
= 5DBA
h
Selection of the error responses for application error messages
• An application error message is tripped by a FALSE-TRUE edge at the binary inputs bSetError1...2.
Selection list
0 No Reaction
1Fault
2Trouble
4 WarningLocked
Subcodes Lenze setting Info
C00581/1 1: Fault LS_SetError_1
: Resp. bSetError1
C00581/2 1: Fault LS_SetError_1
: Resp. bSetError2
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00592 | Resp. to CAN bus connection
Data type: UNSIGNED_8
Index: 23983
d
= 5DAF
h
Configuration of monitoring of the CAN interface (group 1)
System bus "CAN on board"
Selection list
0 No Reaction
1Fault
2Trouble
4 WarningLocked
Subcodes Lenze setting Info
C00592/1 0: No Reaction Response to incorrect telegram for CAN communication
C00592/2 0: No Reaction Response to "BusOff" (bus system switched off)
C00592/3 0: No Reaction Response to warnings of the CAN controller
C00592/4 0: No Reaction Response to communication stop of a CAN bus node
C00592/5 0: No Reaction Response to an event in the case of monitoring via heart-
beat protocol