10 Parameter reference
10.2 Parameter list | C00517
281
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00517
C00565
Parameter | Name:
C00517 | User menu
Data type: INTEGER_32
Index: 24058
d
= 5DFA
h
When a system is installed, parameters must be changed time and again until the system runs satisfactorily. The
user menu of a device serves to create a selection of frequently used parameters to be able to access and change
these parameters quickly.
For setting "0" no entry is displayed in the user menu.
Setting range (min. value | unit | max. value)
0 994
Subcodes Lenze setting Info
C00517/1 51 C00051
: Display of actual speed value
C00517/2 53 C00053
: Display of DC-bus voltage
C00517/3 54 C00054
: Display of motor current
C00517/4 61 C00061
: Display of heatsink temperature
C00517/5 137 C00137
: Display of device state
C00517/6 0 User menu: entry 6
C00517/7 0 User menu: entry 7
C00517/8 11 C00011
: Reference speed
C00517/9 39 C00039/1
: Fixed setpoint 1
C00039/2
: Fixed setpoint 2
C00039/3
: Fixed setpoint 3
C00517/10 0 User menu: entry 10
C00517/11 12 C00012
: Acceleration time main setpoint
C00517/12 13 C00013
: Deceleration time main setpoint
C00517/13 15 C00015
: V/f base frequency
C00517/14 16 C00016
: Vmin boost
C00517/15 22 C00022
: Imax in motor mode
C00517/16 120 C00120
: Motor overload threshold (I
2
xt)
C00517/17 87 C00087: Rated motor speed
C00517/18 99 C00099
: Display of firmware version
C00517/19 0 User menu: entry 19
C00517/20 0 User menu: entry 20
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00565 | Resp. to mains phase failure
Data type: UNSIGNED_8
Index: 24010
d
= 5DCA
h
Response to the failure of mains phases
Selection list (Lenze setting printed in bold)
0 No Reaction
1Fault
4 WarningLocked
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1