10 Parameter reference
10.2 Parameter list | C00359
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00359
C00360
Parameter | Name:
C00359 | CAN status
Data type: UNSIGNED_8
Index: 24216
d
= 5E98
h
System bus "CAN on board"
Selection list (read only)
0 Operational
1 Pre-Operat.
2 Reserved
3 Reserved
4 BootUp
5 Stopped
6 Reserved
7 Reset
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00360 | CAN telegram counter
Data type: UNSIGNED_16
Index: 24215
d
= 5E97
h
System bus "CAN on board"
Display range (min. value | unit | max. value)
0 65535
Subcodes Info
C00360/1 All PDOs/SDOs transmitted
C00360/2 All PDOs/SDOs received
C00360/3 CAN1_OUT telegram counter
C00360/4 CAN2_OUT telegram counter
C00360/5 Reserved
C00360/6 SDO1 OUT telegram counter
C00360/7 SDO2 OUT telegram counter
C00360/8 CAN1_IN telegram counter
C00360/9 CAN2_IN telegram counter
C00360/10 Reserved
C00360/11 SDO1 IN telegram counter
C00360/12 SDO2 IN telegram counter
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1