Parameter reference
Parameters relevant for CANopen communication
80
Lenze · Decentralised frequency inverter 8400 motec (CANopen option) · EDS84DMOTCAN EN 4.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00366
C00367
C00368
C00369
Parameter | Name:
C00366 | Number of CAN SDO channels
Data type: UNSIGNED_8
Index: 24209
d
= 5E91
h
Available from firmware version 02.00 onwards.
Selection of the number of active parameter data channels
In the Lenze setting complying with CANopen, only parameter data channel 1 is active. In order to activate both
parameter data channels, set the selection "2 SDO Lenze".
Representation of the CANopen objects I-1201
(see DS301 V4.02)
Selection list (Lenze setting printed in bold) Info
01 SDO CANopen I-1201
Subindex1.Bit31 = 1 (client -> server (rx))
Subindex2.Bit31 = 1 (server -> client (tx))
Bit 31 = 1 (SDO invalid/not available)
1 2 SDO Lenze I-1201
Subindex1.Bit31 = 0 (client -> server (rx))
Subindex2.Bit31 = 0 (server -> client (tx))
Bit 31 = 1 (SDO valid/available)
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C00367 | CAN sync Rx identifier
Data type: UNSIGNED_16
Index: 24208
d
= 5E90
h
Identifier by means of which the sync slave is to receive sync telegrams.
Mapping of the CANopen object I-1005
(see DS301 V4.02).
PDO synchronisation via sync telegram
( 51)
Setting range (min. value | unit | max. value) Lenze setting
128 255 128
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C00368 | CAN sync-Tx identifier
Data type: UNSIGNED_16
Index: 24207
d
= 5E8F
h
Identifier by means of which the sync master is to transmit sync telegrams.
Mapping of the CANopen object I-1005
(see DS301 V4.02).
PDO synchronisation via sync telegram
( 51)
Setting range (min. value | unit | max. value) Lenze setting
128 255 128
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C00369 | CAN sync transmission cycle time
Data type: UNSIGNED_16
Index: 24206
d
= 5E8E
h
Cycle during which the sync master is to transmit sync telegrams.
If "0 ms" is set (Lenze setting), no sync telegrams are generated.
Mapping of the CANopen object I-1006
(see DS301 V4.02).
PDO synchronisation via sync telegram
( 51)
Setting range (min. value | unit | max. value) Lenze setting
0 ms 65000 0ms
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT