EasyManua.ls Logo

Lenze 9300 vector - Page 314

Lenze 9300 vector
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
Code table
8
8.5
8.5−25
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0361 0 {1 %} 100 System bus load
l Read only
l For a perfect operation, the
entire bus load (all nodes
connected) should be less
than 80 %
1 Load OUT All telegrams sent
2 Load IN All telegrams received
3 Load OUT1 Telegrams sent on CAN−OUT1
4 Load OUT2 Telegrams sent on CAN−OUT2
5 Load OUT3 Telegrams sent on CAN−OUT3
6 Load POUT1 Telegrams sent on parameter
channel1
7 Load POUT2 Telegrams sent on parameter
channel2
8 Load IN1 Telegrams received from
CAN−IN1
9 Load IN2 Telegrams received from
CAN−IN2
10 Load IN3 Telegrams received from
CAN−IN3
11 Load PIN1 Telegrams received from
parameter channel1
12 Load PIN2 Telegrams received from
parameter channel2
C0364
CFG: CAN activ 1000 FIXED0 Selection list 2 Configuration − digital input
signal
l Switches the system bus via
the external signal from
"Pre−Operational" to
"Operational"
C0365 DIS:CAN activ
0 Pre−Operational
System bus state
l Display only
1 Operational
C0366 Sync Response 1
0 No response
Response to sync telegram of
the master
1 Response
C0367 Sync Rx ID 128 1 {1} 256 Receipt identifier (Rx)
l Sync Identifier for grouping
for data transfer to CAN−IN1
C0368 Sync Tx ID 128 1 {1} 256 Transmission identifier (Tx)
l Identifier for generating a
sync telegram
C0369 Sync Tx Time 0 0 {1} 65000 Sync transmission time (Tx)
l Transmission interval for the
object set in C0368
C0400 DIS: OUT −199.99 {0.01 %} 199.99 Analog output signal, function
block AIN1
l Read only
See System
Manual
(extension)
C0402
CFG: OFFSET 19502 FCODE−26/1 Selection list 1 Configuration offset, function
block AIN1
l The offset is added to the
input signal at AIN1−IN
C0403
CFG: GAIN 19504 FCODE−27/1 Selection list 1 Configuration of gain, function
block AIN1
l The gain is multiplied by the
input signal at AIN1−IN
C0404 −199.99 {0.01 %} 199.99
Function block AIN1
l Display of the signals linked
in C0402 and C0404
1 DIS: OFFSET
2 DIS: GAIN
efesotomasyon.com - Lenze

Table of Contents

Other manuals for Lenze 9300 vector