Configuration
Code table
8
8.5
8.5−25
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0361 0 {1 %} 100 System bus load
l Read only
l For a perfect operation, the
entire bus load (all nodes
connected) should be less
than 80 %
1 Load OUT All telegrams sent
2 Load IN All telegrams received
3 Load OUT1 Telegrams sent on CAN−OUT1
4 Load OUT2 Telegrams sent on CAN−OUT2
5 Load OUT3 Telegrams sent on CAN−OUT3
6 Load POUT1 Telegrams sent on parameter
channel1
7 Load POUT2 Telegrams sent on parameter
channel2
8 Load IN1 Telegrams received from
CAN−IN1
9 Load IN2 Telegrams received from
CAN−IN2
10 Load IN3 Telegrams received from
CAN−IN3
11 Load PIN1 Telegrams received from
parameter channel1
12 Load PIN2 Telegrams received from
parameter channel2
C0364
CFG: CAN activ 1000 FIXED0 Selection list 2 Configuration − digital input
signal
l Switches the system bus via
the external signal from
"Pre−Operational" to
"Operational"
C0365 DIS:CAN activ
0 Pre−Operational
System bus state
l Display only
1 Operational
C0366 Sync Response 1
0 No response
Response to sync telegram of
the master
1 Response
C0367 Sync Rx ID 128 1 {1} 256 Receipt identifier (Rx)
l Sync Identifier for grouping
for data transfer to CAN−IN1
C0368 Sync Tx ID 128 1 {1} 256 Transmission identifier (Tx)
l Identifier for generating a
sync telegram
C0369 Sync Tx Time 0 0 {1} 65000 Sync transmission time (Tx)
l Transmission interval for the
object set in C0368
C0400 DIS: OUT −199.99 {0.01 %} 199.99 Analog output signal, function
block AIN1
l Read only
See System
Manual
(extension)
C0402
CFG: OFFSET 19502 FCODE−26/1 Selection list 1 Configuration offset, function
block AIN1
l The offset is added to the
input signal at AIN1−IN
C0403
CFG: GAIN 19504 FCODE−27/1 Selection list 1 Configuration of gain, function
block AIN1
l The gain is multiplied by the
input signal at AIN1−IN
C0404 −199.99 {0.01 %} 199.99
Function block AIN1
l Display of the signals linked
in C0402 and C0404
1 DIS: OFFSET