Wiring the standard device
Wiring of the feedback system
Incremental encoder with TTL level at X8
5
5.11
5.11.2
5.11-2
EDSVF9333V EN 3.0-06/2005
5.11.2 Incremental encoder with TTL level at X8
Field Values
Connectable incremental
encoder
Incremental encoder with TTL level
z Encoder with two 5 V complementary signals electrically
offset by 90°
z Connection of zero track is possible (optional)
Connection at drive controller 9-pole Sub-D socket
Input frequency 0 ... 500 Nm
Current consumption 6 mA per channel
Internal voltage source
(X8/4, X8/5)
5 V DC / max. 200 mA
B
V
CC
GND
Z
+KTY
-KTY
1
2
3
4
5
6
7
8
9
A
X8
<50m
A
A
A
B
Z
B
B
Z
Z
KTY
9300VEC018
Fig. 5.11-1 Connection of incremental encoder with TTL level
c Signals with CW rotation
Cores twisted in pairs
Assignment of 9-pole Sub-D socket (X8) at the controller
Pin 1
2 3 4 5 6 7 8 9
Signal B A A V
CC
GND
(-KTY)
Z Z +KTY B
0.14 mm
2
(AWG 26) 1mm
2
(AWG 18) 0.14 mm
2
(AWG 26)