Technical data
General data/operating conditions
3
3.1
3.1-4
EDSVF9333V EN 3.0-06/2005
Field Values
Coil voltage at +20 °C DC 24 V (20 ... 30 V)
Coil resistance at +20 °C 823 Ω ±10 %
Rated coil power approx. 700 mW
Max. switching voltage AC 250 V, DC 250 V (0.45 A)
Max. AC switching capacity 1500 VA
Max. switching current (ohmic
load)
AC 6 A (250 V), DC 6 A (50 V)
Recommended minimum load >50mW
Max. switching rate 6 switchings per minute
Electrical service life
10
5
switching cycle at 6 A
10
6
switching cycles at 1 A
107 switching cycles at 0.25 A
at 250 V AC
(ohmic load)
6×10
3
switching cycles at 6 A
10
6
switching cycles at 3 A
1.5×10
6
switching cycles at 1 A
107 switching cycles at 0.1 A
at 24 V DC
(ohmic load)
Mechanical life time 10
7
switching cycles
Safety relay K
SR