Configuration
Code table
8
8.3
8.3-17
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0168 Display of the fault messages in
the history buffer
z Keypad: LECOM error number
See System
Manual
(extension)
1 Fail No. act Active fault
2 Fail no. old1 Last fault
3 Fail no. old2 Second to last fault
4 Fail no. old3 Third last fault
5 Fail no. old4 Fourth-last fault
6 Fail no. old5 Fifth-last fault
7 Fail no. old6 Sixth-last fault
8 Fail no. old7 Last but six fault
C0169
Display in [s]
Displays at what time the fault
(C0168) has occurred since mains
connection (C0179)
z If a fault is followed by
another fault for several times,
only the time of the last
occurrence is stored
1 Failtime act Active fault
2 Failtime old1 Last fault
3 Failtime old2 Second to last fault
4 Failtime old3 Third last fault
5 Failtime old4 Fourth-last fault
6 Failtime old5 Fifth-last fault
7 Failtime old6 Sixth-last fault
8 Failtime old7 Last but six fault
C0170 Displays how many times the
fault (C0168) has occurred after
the last mains connection
1 COUNTER ACT Active fault
2 COUNTER OLD1 Last fault
3 Counter old2 Second to last fault
4 Counter old3 Third last fault
5 Counter old4 Fourth-last fault
6 Counter old5 Fifth-last fault
7 Counter old6 Sixth-last fault
8 COUNTER OLD7 Last but six fault
C0173
UG limit 1
Adaptation of UG thresholds
Check during commissioning and
adapt, if necessary
All controllers in the system must
have the same threshold!
See System
Manual
(extension)
Mains LU OU
0 < 400 V 285 V 770 ... 775 V
Device with or without brake
chopper
1 400 V 285 V 770 ... 775 V
2 460 V 328 V 770 ... 775 V
3 480 V 342 V 770 ... 775 V Device without brake chopper
4 480 V 342 V 800 ... 785 V Device with brake chopper
C0178 OP TIMER {s} Display only
Total time of the controller
enable (X5/28 = HIGH)
C0179 MAINS TIMER {s} Display only
Total time of mains ”ON”

Table of Contents