Configuration
Function blocks
Master frequency processing (DFSET)
8
8.2
8.2.5
8.2-21
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0536 -32767 {1} 32767
Function block DFSET
z Display of the signals linked in
C0521, C0522 and C0523
8.2-18
1 DIS: VP-DIV
2 DIS: RAT-DIV
3 DIS: A-trim
C0537 DIS: n-trim -199.99 {0.01 %} 199.99 Function block DFSET
z Display of the signal linked in
C0524
C0538 0 1
Function block DFSET
z Display of the signals linked in
C0525, C0526 and C0527
1 DIS: 0-pulse
2 DIS: RESET
3 DIS: SET
C0539 DIS: IN -6000 {1 rpm} 6000 Function block DFSET
z Display of the signal linked in
C0520
C0546 Min inc/rev 1000 1 {1 inc.} 2147483647 Masking of the touch probe
signal, function block DFSET
z Suppressing interference
pulses at X5/E4 (actual pulse of
touch probe signal)
z Thesizeofthemasking
window between two actual
pulses is set
8.2-18