EasyManua.ls Logo

Lenze EVF9324

Lenze EVF9324
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
Function blocks
Internal motor control with vector control (MCTRL2)
8
8.2
8.2.7
8.2-70
EDSVF9333V EN 3.0-06/2005
Function procedure
0
1
5
2
3
4

C0036
9300vec089
Fig. 8.2-25 Signal sequence with DC injection braking
Actual speed value of the motor (e. g. MCTRL-NACT)
Controller output current (e. g . MCTRL-IACT)
Pulse inhibit (e. g. DCTRL-IMP)
Activating DC injection braking (MCTRL-GSB)
DC injection braking is active (MCTRL-GSB-OUT)
MCTRL-GSB-OUT = HIGH: Function is active
MCTRL-GSB-OUT = LOW: Function is not active
c The m otor rotates with the preset speed. The current adjusts itself as a
function of the load .
d DC injection braking is activated w ith MCTRL-GSB = HIGH. Pulse inhibit
is set. The motor coasts.
e The pulse inhibit is deactivated and the DC braking current set in C0036 is
injected
f DC injection braking is deactivated w ith MCTRL-GSB = LOW
The motor is accelerated to speed setpoint at the set acceleration ramp and
is kept there.

Table of Contents