EasyManua.ls Logo

Lenze EVF9324

Lenze EVF9324
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
Code table
8
8.3
8.3-34
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0547 DIS: AN-IN -199.99 {0.01 %} 199.99 Function block DFOUT
z Display of the signal linked in
C0541
8.2-8
C0548 DIS: SYN-RDY 0 1 Function block DFOUT
z Display of the signal linked in
C0544
C0549 DIS: DF-IN -32767 {1 rpm} 32767 Function block DFOUT
z Display of the signal linked in
C0542
C0560 -199.99 {0.01 %} 199.99
Configuration of fixed setpoints,
function block FIXSET1
z Output of the setpoints to
FIXSET1-OUT via binary coding
of the inputs FIXSET1-IN1 ...
FIXST1-IN4
See System
Manual
(extension)
1 FIX SET-VALUE 100
2 FIX SET-VALUE 75
3 FIX SET-VALUE 50
4 FIX SET-VALUE 25
5 FIX SET-VALUE 0
... ... 0
15 FIX SET-VALUE 0
C0561
CFG: AIN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block FIXSET1
z The analog input signal is
switched to FIXSET1-OUT if all
inputs FIXSET-INx = LOW
C0562
Selection list 2 Configuration of digital input
signals, function block FIXSET1
z The number of inputs to be
assigned depend on the
number of the fixed setpoints
required.
1 CFG: IN 1000 FIXED0 FIXSET1-IN1
2 CFG: IN 1000 FIXED0 FIXSET1-IN2
3 CFG: IN 1000 FIXED0 FIXSET1-IN3
4 CFG: IN 1000 FIXED0 FIXSET1-IN4
C0563 DIS: AIN -199.99 {0.01 %} 199.99 Function block FIXSET1
z Display of the signal linked in
C0561
C0564 0 1 Function block FIXSET1
z Display of the signals linked in
C0562/1, C0562/2, C0562/3
and C0562/4
1 DIS: IN FIXSET1-IN1
2 DIS: IN FIXSET1-IN2
3 DIS: IN FIXSET1-IN3
4 DIS: IN FIXSET1-IN4
C0570
CFG: IN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block S&H1
See System
Manual
(extension)
C0571
CFG: LOAD 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block S&H1
C0572 DIS: IN -199.99 {0.01 %} 199.99 Function block S&H1
z Display of the signal linked in
C0570
C0573 DIS: LOAD 0 1 Function block S&H1
z Display of the signal linked in
C0571
C0574 MONIT OC2 0
0 TRIP
Configuration of monitoring OC2,
earth fault
See System
Manual
(extension)
3 Off

Table of Contents

Related product manuals