Commissioning
Adjusting the motor
Entry of motor data
6
6.6
6.6.1
6.6-2
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0090
Mot voltage Æ 0 {1 V} 1000 Rated motor voltage
Æ depending on C0086
z Motor selection in C0086 sets
the corresponding rated motor
voltage in C0090
z Change of C0090 sets C0086 =
0
6.6-1
C0091
Mot cos phi Æ 0.50 {0.01 } 1.00 Motor cos ϕ
Æ depending on C0086
z Motor selection in C0086 sets
the corresponding motor cos ϕ
in C0091
z Change of C0091 sets
C0086 = 0
6.6-1
Choose similar motor
in C0086 according to the
criteria circuit configuration
and rated motor power
Operating mode "87 Hz
delta connection”?
Does C0086 contain
the motor?
Enter motor nameplate data:
C0081 = 3 x P
C0087 = ( 3 - 1) n + n
C0088 = I
C0089 = 87 Hz
C0090 = U
C0091 = cos
r
0r
r
r
Ö
Ö
j
D
D
Enter motor nameplate data:
C0081, C0087, C0088, C0089,
C0090, C0091
Start entry motor data
Entry motor data completed
Choose motor in C0086
yes
yes
no
no
9300vec096
Fig. 6.6-1 Sequence diagram for motor data entry
P
N
Rated motor power
n
0
Synchronous speed
n
N
Rated motor speed
I
N
Δ
Rated motor current for delta connection
U
N
Δ
Rated motor voltage f or delta connection
Sequence of the motor data
entry

Table of Contents