EasyManua.ls Logo

Lenze EVF9324

Lenze EVF9324
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Wiring the standard device
Wiring of the feedback system
Incremental encoder with HTL level at X9
5
5.11
5.11.3
5.11-3
EDSVF9333V EN 3.0-06/2005
5.11.3 Incremental encoder with HTL level at X9
Field Values
Connectable incremental
encoder
Incremental encoder with HTL-level
z Two-track with inverse signals and zero track
z Single-track without inverse signals and zero track
Connection at drive controller 9-pole Sub-D socket
Input frequency 0 ... 200 Nm
Current consumption 5 mA per channel
Supply of incremental encoder External voltage source
Internal voltage source
(X9/4, X9/5)
5 V DC / max. 200 mA
Total current at X9/4, X9/5 and X10/4, X10/5: max. 200 mA
B
GND
Z
1
2
3
4
5
6
7
8
9
A
X9
<50m
A
B
Z
+
A
A
B
Z
B
Z
9300VEC020
Fig. 5.11-2 Connection of incremental encoder with HTL level
c Signals with CW rotation
d Externalvoltagesourcefortheincrementalencoder
Cores twisted in pairs
Assignment of 9-pole Sub-D socket (X9) at the controller
Pin 1
2 3 4 5 6 7 8 9
Signal B A A +5 V GND Z Z - B
0.14 mm
2
(AWG 26) 1mm
2
(AWG 18) 0.14 mm
2
(AWG 26)
Note!
Connection of single-track incremental encoder with HTL level:
ƒ Place the signal A at pin X9/2 (A) and the signal B at
pin X9/9 (B
).
ƒ Wire pin X9/3 (A) and X9/1) (B) with the positive terminal of
the external voltage source for the incremental encoder.
Technical data
Wiring

Table of Contents

Related product manuals