Single−axis controllers
General data and operating conditions
3
35
EDS94SPP101 EN 10.2
Supply conditions "Single Drive"
AC mains operation Device size 1 ... 7: Direct connection
Device size 81 ... 91: Direct connection via terminals with
wire end ferrules; alternatively via ring cable lugs
DC−bus operation Device size 1 ... 7: Direct connection via terminals or busbar
system (retrofittable)
Device size 81 ... 91: Direct connection via terminals with
wire end ferrules; alternatively via ring cable lugs
For more information, please see the chapter DC−bus
operation.
Power systems
TT
Operation allowed without restrictions.
TN
IT Up to device size 83: additional measure necessary inside
device (see "Earthing of internal EMC filter", 108)
device size 91: Specify when ordering
Motors EN 60034 Only use motors that are suitable for inverter operation.
Insulation strength: max. û 1.5 kV, max. du/dt 5 kV/s
Operating conditions
Environmental conditions
Climate
Storage
IEC/EN 60721−3−1 1K3 (−25 ... +60 °C)
Transport IEC/EN 60721−3−2 Device size 1 ... 6: 2K3 (−25 ... +70 °C)
Operation IEC/EN 60721−3−3 3K3 (−10 ... +55 °C)
Current derating at +45 ... +55 °C:
Device size 1 ... 7: 2.5 %/°C
Device size 81 ... 91: 1 %/°C
Site altitude 0 ... 4000 m amsl
Device size 1 ... 7 with 1000 ... 4000 m amsl: Current derating
5 %/1000 m
Device size 81 ... 91 with 1000 ... 4000 m amsl: Current
derating 10 %/1000 m
Pollution EN 61800−5−1 Degree of pollution 2
Vibration resistance (9.81 m/s
2
= 1 g)
Transport
(only tested for device
size 1 ... 7)
IEC/EN 60721−3−2 2M2
EN 61800−2
2 ... 9 Hz: Amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s
2
200 ... 500 Hz: acceleration resistant up to 15 m/s
2
Operation
Germanischer Lloyd 5 ... 13.2 Hz: Amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g
Device size 81 ... 83: Mounting must be executed with
vibration dampers by the customer. Please consult Lenze.
Device size 91: The control cabinet has to be
vibration−damped.
IEC/EN 60068−2−6
10 ... 57 Hz: Amplitude 0.075 mm
57 ... 150 Hz: Acceleration resistant up to 1 g