EasyManua.ls Logo

Leuze electronic BPS 307i - Display Indicators

Leuze electronic BPS 307i
95 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Device description
Leuze electronic BPS 307i 17
Table 3.1: Meaning of the LED indicators on the device housing
3.3.2 Display indicators
The optional display of the BPS is only used as a display element. The display has the following features:
Monochromatic with white background lighting
Double line, 128 x 32 pixels
Display language: English
Two control buttons can be used to control which values appear in the display.
The background lighting is activated by pressing any control button and is automatically deactivated after
ten minutes have passed.
The display shows the content on two lines:
The upper display line shows the selected function as an English term.
The lower display line shows the data of the selected function.
1 Display
2 Control buttons
Figure 3.7: Display on the device housing
LED Color, state Description
LED 1
PWR
Off Device is switched off
No supply voltage
Green, flashing Device is being initialized
Supply voltage connected
Initialization running
No measurement value output
Green, continuous light Device in operation
Initialization finished
Measurement value output
Red, flashing Warning set
No measurement (e.g. no bar code tape)
Orange, continuous
light
Service active
No data on the host interface
Configuration via USB service interface
LED 2
BUS
Off No supply voltage
Green, flashing Initialization of the host interface
No communication
Green, continuous light Host interface active
Communication possible
Red, flashing Communication error detected