EasyManua.ls Logo

Leuze electronic BPS 307i - Bar Code Tape

Leuze electronic BPS 307i
95 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Leuze electronic BPS 307i 80
Table 13.9: Electrical equipment
Table 13.10: Ambient temperature
13.2 Bar code tape
Table 13.11: BCB dimensions
Table 13.12: BCB structure
Operating voltage U
B
18 … 30 VDC
Power consumption Max. 17.7 W
Structure of the heating Housing heating and separate heating of the optics glass
Warmup time Minimum 30 min at +24 VDC and an ambient temperature
of -35 °C
Minimum conductor cross section Conductor cross section of at least 0.75 mm² for the sup-
ply voltage supply line.
Note:
Wiring through of the voltage supply to multiple heating
devices is not permissible.
Standard, M12 ready-made cable not usable (insufficient
conductor cross section).
Ambient temperature (operation) -35 °C … +50 °C
Ambient temperature (storage) -35 °C … +70 °C
BCB BCB8
Grid 40 mm 30 mm
Standard height 47 mm 47 mm
Preferred heights 25 mm,
Special heights for lengths
greater than 150 m
25 mm, 30 mm, special
heights for lengths greater
than 150 m
Length 0 … 5 m, 0 … 10 m,
0 … 20 m, …, 0 … 150 m,
0 … 200 m;
Special lengths and special
codings for lengths greater
than 150 m (see chapter 14)
0 … 5 m, 0 … 10 m,
0 … 20 m, …, 0 … 150 m;
Special lengths and special
codings for lengths greater
than 150 m (see chapter 14)
Tape tolerance
1 mm per meter 1 mm per meter
NOTICE
Twin tapes on request
Twin tapes can be ordered on request (see chapter 14).
Manufacturing process Filmsetting
Surface protection Polyester, matt
Base material Polyester film, affixed without silicone

Table of Contents

Related product manuals