Basic configuration
Leuze electronic BPS 307i 55
1 Slide switch S1
Factory setting: Gray encoding
2 Hexadecimal rotary switch S2
Factory setting: switch position
0
, i.e., configuration via webConfig tool
Figure 8.3: Operational controls of connection hood MK 307
Slide switch S1
Change the measurement value encoding
• S1 up: Gray encoding
• S1 down: binary encoding
Rotary switch S2
Table 8.1: Configuration via rotary switch S2
NOTICE
Hexadecimal rotary switch S2 for setting the resolution and speed monitoring!
Set the resolution of the position measurement and speed monitoring via rotary switch S2.
1 2
Switch position Position resolution
[mm]
Maximum speed
[m/s]
Level of the switch-
ing output
Speed monitoring
0 Configuration via webConfig tool
1 0.01 webConfig webConfig webConfig
2 0.1 webConfig webConfig webConfig
3 1 webConfig webConfig webConfig
4 10 webConfig webConfig webConfig
5 webConfig webConfig webConfig webConfig
6 webConfig webConfig webConfig webConfig