Device parameters and interfaces
50 BPS 34 Leuze electronic
Table 8.1: Overview of the GSD modules
M22
Page 82
Speed
measurement
control
(P) Speed measurement start mode
(P) Speed measurement stop mode
(I) Speed measurement state
(O) Start event
(O) Stop event
(O) Min./max. speed mode
(O) Min./max. speed reset
M23
Page 84
Speed
measurement
status
(I) Measurement error
(I) Limit value status 1 exceeded
(I) Limit value status 2 exceeded
(I) Limit value status 3 exceeded
(I) Limit value status 4 exceeded
(I) Dynamic limit value status exceeded
(I) Movement status
(I) Direction of movement
(I) Compare limit value state 1
(I) Compare limit value state 2
(I) Compare limit value state 3
(I) Compare limit value state 4
(I) Compare dynamic limit value state
M24
Page 86
Min./max.
speed
(I) Minimum speed
(I) Maximum speed
M25
Page 87
Static speed limit values
(for limit value 1 … 4)
(P) Speed limit value mode (active/not active)
(P) Direction selection (both directions or only one)
(P) Switching type (value is above or below the
defined limits)
(P) Speed limit value
(P) Hysteresis
(P) Range start
(P) Range end
M26
Page 89
Dynamic
speed
limit values
(O) Limit value control
(O) Switching type (value is above or below the
defined limits)
(O) Direction selection
(O) Limit value
(O) Hysteresis
(O) Range start
(O) Range end
M27
Page 91
Tape value correction
(P) Real length
(P) Range start
(P) Range end
Module
Page
Module name Module contents
(P) = Parameter, (O) = Output, (I) = Input