Diagnostic information 2-5
Lexmark S400 Series
1201 Print Incomplete The print carrier stopped before
all of the data was used.
Technical Support Center:
Clear any carrier jams. Unplug the All-In-
One from the wall outlet, wait a few
seconds, then plus the All-In-One back in
and turn the power on. Resend the print
job.
Service:
Clear any carrier jams. Unplug the All-In-
One from the wall outlet, wait a few
seconds, then plus the All-In-One back in
and turn the power on. Resend the print
job.
1202 Data Error Incorrect data has been sent
from the host computer to the
All-In-One.
Technical Support Center:
Unplug the All-In-One from the wall outlet;
wait a few seconds, then plug the All-In-
One back in and turn the power on. If the
problem remains, then replace the USB
cable.
Service:
Replace the system board. See “System
board removal” on page 4-28.
1203 Printhead Short The short test detected a short
circuit in the printhead.
Technical Support Center:
Remove the printhead. Clean and reinstall
the printhead. If this does not correct the
problem, then replace the printhead.
Service:
Remove the printhead. Clean and reinstall
the printhead. If this does not correct the
problem, then replace the printhead.
1204 Printhead Programming Firmware is unable to program
pseudo-random printhead ID.
Technical Support Center:
Replace the printhead.
Service:
Replace the printhead.
1205 Mono TSR Error There is a problem in the color
TSR circuit; cannot determine
printhead temperature.
Technical Support Center:
Replace the printhead.
Service:
Replace the printhead.
1206 Color TSR Error There is a problem in the color
TSR circuit; cannot determine
printhead temperature.
Technical Support Center:
Replace the printhead.
Service:
Replace the printhead.
Error
Code