INSTALLER SETTING
ENGLISH
Domestic hot water - DHW re-circulation
In this menu, the recirculation pump can be activated and the pattern of operation is defined.
Installer level
Setting - Domestic hot water - DHW re-circulation - Enable re-circulation = Use
Setting - Domestic hot water - DHW re-circulation - On = 10 min
Setting - Domestic hot water - DHW re-circulation - Off = 20 min
User level
1. Schedule - DHW Recirculation - Usage = Use
Schedule - DHW Recirculation - Time = 06:00 ~ 07:00
Schedule - DHW Recirculation - Day = Everyday
2. Schedule - DHW Recirculation - Usage = Use
Schedule - DHW Recirculation - Time = 18:00 ~ 20:00
Schedule - DHW Recirculation - Day = Everyday
Example)
Time
Pump Off
Pump On
06:00
08:00
18:00
20:00
10 min On 20 min Off
NOTE
Operation times of the Recirculation pump should be limited to times when comfort is really
needed. If the pump is released for long time, energy consumption may increase a lot due to
heat dissipation into the building and need to re-heat the hot water tank!
NOTE
A schedule (accessible via Main screen) becomes available, after ‘Enable recirculation’ is set to
‘Use’.
NOTE
If you set the start time before the current time, the pump will be activated tomorrow at the set
time.
Example: If you set times as above and it is 19:00 now, the pump will be activated tomorrow at
06:00 for the first time!

Table of Contents

Other manuals for LG HN1639HC NK0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG HN1639HC NK0 and is the answer not in the manual?

LG HN1639HC NK0 Specifications

General IconGeneral
BrandLG
ModelHN1639HC NK0
CategoryHeat Pump
LanguageEnglish

Related product manuals