INSTALLER SETTING
124
INSTALLER SETTING
ENGLISH
Static pressure setting(air conditioner)
Static pressure setting can be set only in the duct products. (It cannot be set in other products.)
• You can set the following setting values using [<,>(left/right)] button.
• 2TH function’s operation characteristics may be different for each product.
Static pressure
Description
Variable / Fixed ESP default value
Variable high static pressure V-H Variable High static pressure(High)
Fixed high static pressure
F-H Fixed High static pressure(High)
Variable low static pressure
V-L Variable Low static pressure(Low)
Fixed low static pressure
F-L Fixed Low static pressure(Low)
Remote controller master / slave setting
(air conditioner / General, DX ventilator)
This function sets configuration for the master/slave setting through the remote controller.
• Change setting values using [<,>(left/right)] button.
• 2TH function’s operation characteristics may be different for each product.
M/S Description
Master (default)
Using group control, the indoor units are operated based on the re-
mote controller.
Slave
Using group control, all remote controllers except 1 master remote
controller are set as slaves.