CHAPTER 1: ALARMS 1-12
A22 – Signal A2 "lathe in automatic mode" interrupted during loading
cycle
SIGNAL A2 (LATHE
IN AUTOMATIC MODE)
INTERRUPTED DURING
LOADING CYCLE!
A22
Description:
The « Signal A2 "lathe in automatic mode" interrupted during loading cycle » alarm is generated if the
signal (I41 – A2) is interrupted in the loading cycle.
Solution:
Verify the lathe/bar feeder connection.
Verify the wiring of the signal A2.
Check the lathe programming.
QUICK LOAD SERVO 65/80