Chapter 8. Installation and Testing Operation
8-2
8.1.2 Install Rnet I/F slave module
In the types of slave module, there are electric communication modules of G3L-RREA, G4L-RREA,
G6L-RREA.
Extension base is not available in the GLOFA GM3/GM4 and MASTER-K K1000/K300S and only
basic base is available. Slave configuration is impossible in the GMR/GM1/GM2.
[Table 8.1.2] indicates the modules that can be used with slave and each module can be equipped at
the all slot location.
[Table 8.1.2] module model name for slave configuration
Available module name Unavailable module name
Itme Itme Type name
Cordinate module GM1-CORA
All I/O module
Interface module ALL
A/D, D/A conversion module Interupt module G □F-INTA
TC,RTD module Fnet, Enet, Dnet, Pnet module
G □L-FUEA/FUOA
G □L-EUEA/DUEA
PID control module G □F-PIDA
Analog timer G □F-AT□A
Cnet module G □L-CUEA
High-speed counter module
(When using GLOFA network)
High-speed counter module
(When using MASTER-K
network)
G □F-HSCA
※ 3,4,6 can be inserted into ‘□’ in the type name.
※ High-speed counter module can be used in the network bu GLOFA CPU. MASTER-K
CPU can’t use it.
※ For how to equip the base module, refer to the each CPU manual.