14. Specifications
14-2
SV-iC5
Multi-function relay
terminal
Fault output (N.O., N.C.)
Analog output 0 ~ 10 Vdc : Frequency, Current, Voltage, DC link voltage selectable
Protective functions
Inverter Trip
Over-voltage, Under-voltage, Over-current, Ground fault current detection, Over-temperature of inverter
and motor, Output phase open, Overload, Communication error, Loss of frequency command, H/W fault
Alarm
Conditions
Stall prevention, Overload
Momentary
power loss
Less than 15 msec : Continuous operation
More than 15 msec : Auto Restart enable
Environment
Cooling
method
Forced air cooling
Degree of
protection
Open, Pollution degree 2
Ambient
temperature
-10°C ~ +50°C
Storage
temperature
-20°C ~ +65°C
Relative
humidity
Less than 90% (no condensation)
Altitude,
Vibration
1,000m above sea level, Max. 5.9m/sec
2
(0.6G)
Application
site
Protected from corrosive gas, combustible gas, oil mist or dust

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LS Industrial Systems SV iC5 Series and is the answer not in the manual?

LS Industrial Systems SV iC5 Series Specifications

General IconGeneral
BrandLS Industrial Systems
ModelSV iC5 Series
CategoryInverter
LanguageEnglish

Related product manuals