5-17
H77
A34D [Cooling
fan
control]
0 ~ 1 0 Always ON 0 O 8-30
1 Keeps ON when its temp is
higher than inverter protection
limit temp.
Activated only during operation
when its temp is below that of
inverter protection limit.
H78 A34E [Operating
method
select
when
cooling
fan
malfunctio
ns]
0 ~ 1 0
Continuous operation when
cooling fan malfunctions.
0 O 8-31
1 Operation stopped when
cooling fan malfunctions.
H79 A34F [S/W
version]
0 ~ 10.0 This parameter displays the inverter
software version.
1.0 X -
H81
A351 [2
n
motor
Accel
time]
0 ~
6000
[sec]
This parameter actives when the
selected terminal is ON after I17-I24 is
set to 12 {2
nd
motor select}.
5.0 O 8-21
H82 A352 [2
n
motor
Decel
time]
10.0 O
H83 A353 [2
n
motor
base
frequency]
30 ~
400 [Hz]
60.00 X
H84 A354 [2
n
motor
V/F
pattern]
0 ~ 2 0 X
H85 A355 [2
n
motor
forward
torque
boost]
0 ~ 15
[%]
5 X
H86 A356 [2
n
motor
reverse
torque
boost]
5 X
H87 A347 [2
n
motor
stall
prevention
level]
30~150
[%]
150 X 8-21
Exception: Since SV004iG5A-2/SV004iG5A-4 is Natural convection type, this code is hidden.
2)
: It is indicated when choosing I17~I24 as a 12 (2
nd
motor select).
H88 A358 [2
n
motor
Electronic
thermal
level for 1
min]
50~200
[%]
150 O
H89 A359 [2
n
motor
Electronic
thermal
level for
continuou
s]
50~150
[%]
100 O
H90 A35A [2
n
motor
rated
current]
0.1~100
[A]
26.3 X
H91
A35B [Paramete
r read]
0 ~ 1 Copy the parameters from inverter and
save them into remote loader.
0
X
8-32