363-208-011
Cabling, Wiring, and Assembly
Issue 4 February 1997 3-59
Figure 3-40. J204 Wiring (Channel Unit Slots 19 - 24)
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
Unassigned
CH
77/80
81/84
85/88
89/92
93/96
73/76
CP
Slot
Quad
Unit/Ch
19/4
20/1
20/2
20/3
20/4
21/1
21/2
21/3
21/4
22/1
22/2
22/3
22/4
23/1
23/2
23/3
23/4
24/1
24/2
24/3
24/4
Shelf 2, 4, 6, or 8
J204
50
45
40
35
30
26 1
5
10
15
20
25
WIRING SIDE
W/BL
W/O
W/G
W/BR
W/S
R/BL
R/O
R/GR
Y/O
Y/GR
Y/BR
Y/S
V/BL
V/O
V/GR
V/BR
V/S
BL/W
O/W
G/W
BR/W
S/W
BL/R
O/R
GR/R
O/Y
GR/Y
BR/Y
S/Y
BL/V
O/V
GR/V
BR/V
S/V
BR/R
S/R
BL/BK
O/BK
G/BK
BR/BK
S/BK
BL/Y
R/BR
R/S
BK/BL
BK/O
B K/G
BK/BR
BK/S
Y/BL