3-14 Issue 4 February 1997
363-208-011
Cabling, Wiring, and Assembly
Bay Local Cable Connections
The following sections detail each installer operation necessary to interconnect
the Standard Bay Cables and the Shelf Dangler Cables. For ease of installation
and to alleviate cable duct congestion these procedures should be followed in the
sequence presented. Details of these procedures are outlined in the respective
sections.
NOTE:
If the bay has been factory assembled (J1C265B-1 or J1C265C-1) then the
following operations are verification items only.
Sections Description of Operations
Power & Ringing Interface Install the Power Interface Unit (ED7C734-30) and its cable
assembly. Mate the cable assembly’s connectors to their
associated shelf dangler cable connectors.
PCM Mate the PCM Intrabay Cable Assemblies [ED7C723-30
Groups 9() to 12()] connectors to their associated MDS shelf
connectors.
Test Access Install the TAP Standard Bay Cable Assembly (ED7C723-34
Group 1) and mate its Test Access Path (TAP) connectors to
the associated shelf dangler cable connectors.
Alarms and Telemetry Install TS1 block and ATU interface cables [ED7C723-36
Groups 1(), 3(), 4, 5, and 6].