EasyManuals Logo

Lumel ND30 User Manual

Lumel ND30
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
ND30-09D 53 User's manual
4031 RW
0,1
Alarm output 1 - State of the relay at the alarm
switched on: 0 - relay disabled
1 - relay enabled
1
4032 RW
0,1
Alarm output 1 - alarm deactivation lock 0
4033 RW
0,1
Alarm output 1 - alarm signalization 0
4034 RW 0.1..43
Alarm output 1 - value for the condition 1 (c1)
(code as in Table 8)
38
4035 RW 0..9
Alarm output 1 - type for the condition 1: 0 –
n_on, 1 – noFF,
2 – on, 3 – oFF, 4 – H_on, 5 – HoFF, 6 – 3non, 7
– 3noF,
8 – 3_on, 9 – 3_oF
0
4036 RW
-1440..
0..1440
[
o
/
oo
]
Alarm output 1 - lower value of the condition 1
switch of the rated input range
900
4037 RW
-1440..
0..1440
[
o
/
oo
]
Alarm output 1 - upper value of the condition 1
switch of the rated input range
1100
4038 RW 0..3600 s Alarm output 1 - condition 1 activation delay 0
4039 RW 0..3600 s Alarm output 1 - condition 1 deactivation delay 0
4040 RW 0..3600 s Alarm output 1 - condition 1 re-activation lock 0
4041 RW
0,1
Alarm output 1 - condition 1 signalization 0
4042 RW reserved
4043 RW 0.1..43
Alarm output 1 - value for the condition 2 (c2)
(code as in Table 8)
38
4044 RW 0..9
Alarm output 1 - type for the condition 2: 0 –
n_on, 1 – noFF,
2 – on, 3 – oFF, 4 – H_on, 5 – HoFF, 6 – 3non, 7
– 3noF,
8 – 3_on, 9 – 3_oF
0
4045 RW
-1440..
0..1440
[
o
/
oo
]
Alarm output 1 - lower value of the condition 2
switch of the rated input range
900
4046 RW
-1440..
0..1440
[
o
/
oo
]
Alarm output 1 - upper value of the condition 2
switch of the rated input range
1100
4047 RW 0..3600 s Alarm output 1 - condition 2 activation delay 0
4048 RW 0..3600 s Alarm output 1 - condition 2 deactivation delay 0
4049 RW 0..3600 s Alarm output 1 - condition 2 re-activation lock 0
4050 RW
0,1
Alarm output 1– condition 2 signalization 0
4051 RW reserved
4052 RW 0.1..43
Alarm output 1 - value for the condition 3 (c3)
(code as in Table 8)
38
4053 RW 0..9
Alarm output 1 - type for the condition 3: 0 – n_on,
1 – noFF, 2– on, 3 – oFF, 4 – H_on, 5 – HoFF, 6 –
3non, 7 – 3noF, 8 – 3_on, 9– 3_oF
0