(E) 3
LT10A / LT11A Series
2. Summary
2-1. Features
Compact size suited to inclusion in systems.
DIN size (72 × 72 mm). Can be panel-mounted.
Devices such as PLCs are connectable from the counter
unit.
Go/No Go output is standard to all models. Models
capable of BCD and/or RS-232C also outputs are
available.
Resolution
LT10A series : 0.005 mm (0.0002")
LT11A series : 0.001 mm (0.0001")
As well as the current value, maximum and minimum
values and peak-to-peak values can also be measured.
Add/Sub calculation is standard feature (only for 2
channel models).
Can measure the widths or steps.
Can carry out Go/No Go test on different lots. (BCD
output models.)
Four different upper and lower limits can be stored in
memory for the Go/No Go comparison.
Power is compatible to DC 9 to 24V.
Provided via the power input connector.
Use a power cable less than 10 meters long.
The counter unit LT10A/LT11A series is designed to be
incorporated into assembly lines or jigs, and to be used for
measuring components or Go/No Go.
Use in combination with a DT series measuring unit. Types
are available to suit various uses.
Number of
input channel
1
2
1
2
Model
LT10A-105
LT10A-105B
LT10A-105C
LT10A-205
LT10A-205B
LT10A-205C
LT11A-101
LT11A-101B
LT11A-101C
LT11A-201
LT11A-201B
LT11A-201C
Output
Go/No Go
RS-232C
BCD
Resolution
(mm)
0.005
0.001