74 647852EN-USM1(B-12/2021)
MAINTENANCE
6. Add fluid through filler port (3).
Use a clean funnel and clean the
underside of the oil drum before filling.
7. Put back the cap (1).
8. Visually check that there is no leakage in the tank
and pipes.
Always maintain the fluid level at
maximum as cooling depends on the
fluid flowing through the reservoir.
9. Check the operation of the hydraulic controls.
4.7.5 CHECK BRAKE FLUID LEVEL
WARNING
If the brake fluid level is abnormally low, consult your
dealer.
DANGER
Consult your dealer in case of abnormal operation of the
brakes.
Place the lift truck on level ground.
1. Lift up the braking fluid reservoir access panel (1).
2. Visually check the level.
3. The level is correct when it is at the MAX level on
the tank.
4. If necessary, add fluid through filler port (2).
5. Visually check that there is no leakage in the tank
and pipes.
6. Check the operation of the service brakes.
7. Check the proper operation of the parking brake.
4.8. 50 HOURS OF SERVICE OR
WEEKLY MAINTENANCE
4.8.1 CHECK TRANSMISSION OIL
LEVEL
Place the lift truck on level ground with the
engine stopped.
1. Raise the engine cover.
2. Remove the floor mat.
3. Undo screws (1) to remove the floor (2).
1
2
2
1
1
4.