9-9
GRT8100 SERVICE MANUAL LUBRICATION
9
Published 3/26/2018, Control # 596-05
GROVE
Table 9-4Approved Lubricant Reference Table
Ref. Approved Lubricant
Lube Specification
Down To -9˚C (15˚F)
Lube Specification
Down To TO -29˚C
(-20˚F)
Lube Specification
Down To -40˚C
(-40˚F)
A
Extreme Pressure Multipurpose Grease 6829003477 6829104275 6829104275
B
Gear Lube (GL-5) 6829014058 6829014058 6829014058
C
Fully Formulated Anti-Freeze Coolant 6829101130 6829101130 6829104212
D
Liquid Coolant Conditioner 6829012858 6829012858 6829012858
E
Tractor Hydraulic Fluid 6829006444 6829101559 6829101559
F
Engine Oil SAE 6829104182 (15W-40) 80056036 (0W-40) 80056036 (0W-40)
G
Open Gear Lube 6829102971 6829102971 6829102971
H
Extreme Pressure Gear Lube 6829100213 6829103636 6829103636
J
Hydraulic Oil 6829006444 6829006993 6829006993
K
Diesel Exhaust Fluid (DEF) 80019225 80019225 80019225
L
Extreme Pressure Multipurpose Grease 6829015304 6829104275 6829104275
Item
Lube Point
Description
Figure
No.
Approved
Lubricant
Lube
Capacity
Lube Interval Application
Drive Train
1 Air Cleaner Filter Figure 9-1 --- ---
Replace filter element
when indicator shows
red.
2 Fuel Filter Figure 9-1 --- ---
Change filter every 500
hours or 6 months.
Fuel filter is located
on inside right hand
side of frame beside
engine.
3
Engine
Crankcase
Figure 9-1
F
Tier 3 and
Tier 4
20 L
(21 qt)
Check level every 10
hours or daily
Drain, fill and replace
filter every: 500 hours
(0-500 ppm sulfur fuel);
400 hours
(500-5000 ppm sulfur
fuel); 250 hours
(>5000 ppm sulfur fuel)
Through fill cap to
FULL mark on
dipstick
Refer to Item 6.
4
Engine Cooling
System and SCA
Levels
Figure 9-1 C, D
52.7 L
40 qt
Check coolant level
every 10 hours or daily
Check SCA levels
every 500 hours
Check coolant for
contamination every
1000 hours
Check level in
sight glass at
rear of crane.
Superstructure
must be rotated
to access filler
on top of carrier.

Table of Contents

Other manuals for Manitowoc Grove GRT8100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT8100 and is the answer not in the manual?

Manitowoc Grove GRT8100 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT8100
CategoryConstruction Equipment
LanguageEnglish

Related product manuals