Page 89 P/N 03521015 Rev Q
22. Single XP HFR Hoods with Heavy Loading Filter (HLF) and
optional HFR FCC
WARNING
Use only if package is received unopened and contents are
undamaged. If damage is noted, contact the shipper for replacement
or repair.
Prior to using any MAXAIR
®
System or component, be sure to be
familiar with the system’s NIOSH approved conguration.
DO NOT use if any component is damaged. If any components are
damaged or contaminated and therefore unt for safe and e󰀨ective
use, they should be replaced immediately.
Only trained and experienced personnel who have read and under-
stand the User’s Instructions should use this product.
Failure to follow the User’s Instructions, these and in the MAXAIR
Systems User’s Instructions, P/N 03521015, may be hazardous to
the user’s health.
The institution using this product in any application is responsible for
determining the appropriateness of this equipment relative to regula-
tory requirements. Bio-Medical Devices Intl, Inc. does not recom-
mend the appropriate systems for a particular institution or facility.
Use only MAXAIR Systems/ NIOSH approved compatible
components.
NOT for use in atmospheres immediately dangerous to life or health
(IDLH), and atmospheres containing less than 19.5% oxygen, or
more than 25% oxygen.
Flammability Level I: fabric may burn if exposed to open ame.
Follow current local regulations governing biohazard waste to safely
dispose of used shrouds.
If you need more information, contact your BMDI Sales
Representative, or call BMDI customer service at 1-800-443-3842.
!
Symbol Denitions
Warning, Caution, or Note Order Number
!
Intended Use
The MAXAIR
®
CAPR
®
Hood Systems are intended to lter
aerosolized and droplet particulates and provide high level uid
resistance.
Hoods are designed for single use applications.
Hood Specications
Temperature Limits: 49
0
C maximum
Materials:
Regulatory
NIOSH
Typical Hood System Components
1
2 4
3
1 The 2500-30TSC and 2500-36TSC are alternates to the 2500-37TSC.
O.N. 2271PB-07SM
(Small-Medium)
P/N 07831155
O.N. 2271PB-07ML
(Medium-Large)
P/N 07831156
*one 2170-27 (07831205) HLF is
included with each Hood
O.N. 2271PW-07SM
(Small-Medium)
P/N 07831183
O.N. 2271PW-07ML
(Medium-Large)
P/N 07831184
*one 2170-27 (07831205) HLF
is included with each Hood
1. 2081-03 Helmet
2. 2061-05 HFR FCC
3. 2271PW-07 Hood w/2170-
27 HLF
4. 2500-37TSC Battery
1
5. 2000-76 Battery Belt
6. 2600-01 Battery
Charger
A. 2081-03 Helmet
B. 2061-05 HFR FCC
C. 2271PB-07 Hood w/
2170-27 HLF
D. 2500-37TSC Battery
1
E. 2000-76 Battery Belt
F. 2600-01 Battery
Charger
6
5
B
D
C
F
E
A
MATERIAL TYPE FLUID RESISTANCE
Body (Shroud) Polypropylene ASTM F1671
Lens Polycarbonate ASTM F1671
Hood Filter Polypropylene AATCC TM127
HLF Polypropylene/
modacrylic blend
General particle lter
material
O.N.