EasyManua.ls Logo

Maxair CAPR - DLC Double Shroud; Standard CA-CAPR-36 System with 2261-01 DLC Double Shroud

Maxair CAPR
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 70 P/N 03521015 Rev Q
16. DLC Double Shroud
WARNING
Use only if package is received unopened and contents
are undamaged. If damage is noted, contact the shipper for
replacement or repair.
Prior to using any MAXAIR
®
System or component, be
sure to be familiar with the system’s NIOSH approved
conguration.
Read and understand the User’s Instructions Manual.
Failure to follow the User’s Instructions Manual may be
hazardous to the user’s health.
The institution using this product in any application is
responsible for determining the appropriateness of this
equipment relative to regulatory requirements. Bio-Medical
Devices Intl, Inc. does not recommend the appropriate
systems for a particular institution or facility.
DO NOT use if any component is damaged. If any
components are damaged or contaminated and therefore
unt for safe and e󰀨ective use, they should be replaced
immediately.
Use only MAXAIR Systems/ NIOSH approved compatible
components.
The shrouds are not intended for use against oily particulates
such as paint mist, oil mist or detergents.
NOT for use in atmospheres immediately dangerous to life or
health (IDLH), and atmospheres containing less than 19.5%
oxygen.
Follow current local regulations governing biohazard waste
to safely dispose of used shrouds.
If you need more information, contact your BMDI Sales
Representative, or call BMDI customer service at
1-800-443-3842.
Intended Use
The MAXAIR
®
CAPR
®
Double Shroud Systems are intended to lter
aerosolized and droplet particulates.
Double Shrouds are designed for single use applications.
For Use With
The MAXAIR 2261-01 DLC-Double Shroud is a component of the
MAXAIR CAPR Double Shroud Systems and is intended to be donned
with a MAXAIR CAPR Powered Air Purifying Respirator (PAPR) 2081-
03 Helmet and 2164-10 Filter Cartridge or alternate.
Standard CA-CAPR-36 System with 2261-01 DLC
Double Shroud
* Alternate Filter Cartridges include the 2163-10.
Alternate Batteries include the 2500-37TSC and 2500-30TSC.
Materials
DLC Lens is PETG
DLC Cu󰀨 is Polyurethane
Shroud outer body is plastic coated fabric
Shroud inner body is electrostatic lter media
Specications
Temperature Limits: 49
0
C
Eciency Rang: HE
Regulatory
NIOSH
1
5
6
4
3
2
7
O.N. 2261-01SM
(01031394)
Small-Medium
O.N. 2261-01ML
(01031396)
Medium-Large
1. 2081-03 Helmet and Power
Cord (2081-03 Helmet with
SnapOn Cage removed)
5. 2500-36TSC Battery*
2. 2164-10 Filter Cartridge* 6. 2600-01 Battery Charger
3. 2061-03 Filter Cover Cap 7. 2261-01 Double Shroud
4. 2000-76 Battery Belt

Table of Contents

Other manuals for Maxair CAPR

Related product manuals