EasyManua.ls Logo

Maxon GPSLR Series - Step 5 - Connect Power & Ground Cables to J-Box

Maxon GPSLR Series
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
51
STEP 5 - CONNECT POWER & GROUND CABLES TO
J-BOX
2. Form a drip loop on the fused power
cable where it enters the cable gland
from outside the J-box mounting
plate (FIG. 51-3).
NOTE: Bare wires must not be visible after the heatshrink tubing shrinks on
terminal lug.
J-BOX
CONNECTING FUSED BATTERY POWER CABLE (+) AT J-BOX
FIG. 51-3
3. Insert power (+) cable, from vehicle battery,
through cable gland (FIGS 51-3 and 51-3A).
POWER CABLE (+)
TERMINAL
175 AMP FUSED
POWER CABLE (+)
FIG. 51-3A
CABLE
GLAND
NUT
1. Measure (if needed) and then cut
excess cable from bare wire end of
power (+) and ground (-) cables.
Keep enough length to form a drip
loop in the cables. Put heat shrink
tubing (parts box) (FIG. 51-1) on
the end of the cable (leave room for
terminal lug). Using a proper crimping
tool, crimp copper terminal lug (from
parts box), on the power (+) and
ground (-) cables and shrink the heat
shrink tubing (FIG. 51-2).
PLACING TERMINAL LUG & HEAT SHRINK
TUBING ON FUSED POWER CABLE
FIG. 51-1
TYPICAL FUSED POWER CABLE WITH
TERMINAL LUG INSTALLED
FIG. 51-2
COPPER
TERMINAL LUG
FUSED POWER CABLE
(BARE WIRE END)
HEAT SHRINK TUBING
(P/N 253316-04)
DRIP LOOP
J-BOX
MOUNTING
PLATE
Protect electrical connections on the J-box with a clear corrosion preventative
spray. It must be clear to read the labels for the connections.
NOTICE
DRAFT 05-03-24

Other manuals for Maxon GPSLR Series