McHale V Series Baler
76
If any arrows are displayed when the chamber is empty and closed, then the rollers
may need to be cleaned of any loose material or the sensor zero position may need to
be set. (See ‘Machine setup’)
The total amount of net used is displayed in metres on the main screen. The amount
of net used on each bale is added to the total and displayed on the screen just below
the rotating net symbol.
This counter can be reset in the machine setup menu. (See ‘Machine setup’)
7.4.7 Lube counter
This is a counter to remind the operator to check the chain oil and grease levels. This
counts down from 300 bales and when zero is reached the alarm sounds and a
lubrication symbol is displayed on the screen.
When the alarm sounds, ‘RESET’ will appear above button 2 which should be pressed
to reset the counter after oil and grease levels are checked. To reset the alarm early,
go into the counters menu and press the reset button.
7.4.8 Voltage monitor
The control unit monitors the supply voltage and displays it on the second working
screen. If the voltage falls below a safe operating level, this warning screen is
displayed. The usual causes are a bad battery, defective charging system on the
tractor or loose/corroded connections on the power lead.
7.4.6 Net metres