McHale V Series Baler
83
7.5 Warning messages
Drop floor sensor
As soon as the drop floor moves away from the working
position, this warning will be displayed to alert the operator.
The red light beside button 7 will also flash.
(2002)
Knife pressure too high (V6750/ V8950 only)
This is displayed when the knife pressure is too high for
baling (above 65 bar hydraulic pressure).
It is normal for this warning to be displayed during knife
activation with maximum tractor pressure. It must be
lowered again before baling. (See ‘Knife operation (V6750/
V8950 only)’)
(2003)
Net knife position
This warning is displayed when entering AUTO mode to tell
the operator if the net knife is in the cut position. Net cannot
be fed if the knife is already tripped. (Activating the spool
valve in the door close direction automatically resets the net
knife.)
(2004)
Net error
This warning is displayed when the roll of net runs out or if
the net fails to feed into the chamber. The red light beside
button 5 will also flash. Press button 5 to restart netting and
the warning will disappear once net starts feeding again.
(2006)
Net not cut
This is displayed if the net cut sensor does not observe that
the net has been cut at the end of the netting process.
(2022)