19.1.10. mV Sensor input (NOT MFT1711 or MFT1721)
Specfication Detail
Including temperature
(third party module)
±1.0% ±2 digits
Range 0.0 mV to ±199.9 mV dc
Resolution 0.1 mV
19.1.11. Internal memory (Not MFT1711 or MFT1721)
Specfication Detail
Capacity 1000 results
Bluetooth
®
communication
19.1.12. Power consumption:
Specfication Detail
Nominal minimum: 60 mA (Voltage range with no input voltage)
Nominal maximum: 350 mA (Active Insulation test set to 1000 V / 1 MΩ)
Range: -20 °C to +55 °C
19.1.13. Temperature (via 3rd Party Module)
Specfication Detail
Intrinsic accuracy: ±1.0% ±2 digits
Resolution: 1 °C
Range: -20 °C to +100 °C
19.2 Environmental Specification.
Specfication Detail
Temperature
Operational range: -10 °C to +55 °C
Storage range: -25 °C to +70 °C
Humidity 90% R.H. at +40 °C max.
Altitude 2000 m to full safety specification.
Weight: 1000 g ±10% including batteries but excluding test leads, accessories and
carry case.
Dimensions: 150 mm high x 85 mm wide x 235 mm deep (6 in. x 3.5 in. x 9.5 in.)
IP rating: IP54
Power Supply. Battery: Primary 6 x 1,5 V cells IEC LR6 type (AA alkaline,).
Battery: Rechargeable: 6 x 1.2 VNiMH cells EC HR6. Display shows rechargeable
[NiMH] when the battery type is changed in setup option (Section 10).
Safety / EMC. EMC In accordance with IEC61326 edition 2.
Locations: Class B locations.
Safety in accordance with BS EN 61010 -1 2010 + 61010 -30:2010
Installation Category: 600 V CAT III / 300 V CAT IV. (Max Phase to Phase 550 V)
In addition switch probe and test leads are designed to meet IEC 1010-031:2008, Double insulated to
Installation Category III, 300 V phase to earth, 500 V phase to phase.
www.megger.com
MFT1800 series
66
Specifications