EasyManua.ls Logo

Menvier Security TS690 - View Log (Cont.); Log Event Codes

Menvier Security TS690
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
View Log (Cont.)
1. From the unset (open) mode enter your passcode and press [ENT] twice to select
user menu 2.
2. Whilst user menu 2 is selected. Press [9] to select the view log option.
3. The display will show the most recent event, see log event codes. To navigate through
the log, use the [A] and [C] keys to scroll backwards and forwards.
4. The [B] key can be used to display addition information for the select event, the type
ofinformationdisplayedwilldependontheremotekeypadtypethatisbeingused:
a) When using LCD remote keypads the [B] can be used to display circuit text.
b) When using LED or Starburst remote keypads the [B] can be used to display the
time, date and time (minutes & Seconds).
5. To return the system to the open mode press [ESC] three times.
Log Even t Codes
LCD Starburst LED Description
AC OFF
A.C. OFF
PF
Mains power removed.
AC RESTORED
A.C. ON
Pr
Mains power restored
ACTION ALARM
ALM SENT
AA
Alarm activated when system is part-set.
ALARM 01-38
ALARM 01-38
CA.01-38
Full alarm from circuit (01-38).
AUX/BELL TAMPER
AUX TAMP
AT
Auxiliary tamper activated.
AUXILIARY 01-38
AUX 01-38
Au.01-38
Auxiliary circuit activated.
BATTERY FAULT
BATT FLT
BF
Battery fault (voltage below 10.5V).
BELL TESTED
BELL TST
BT
External bell and strobes tested.
CALL BACK No. 01-03
C. BACK 01-03
CB.01-03
Modem making a call back to remote PC.
CCT OMITTED
OMIT'D 01-38
CO.01-38
Circuits omitted by the user at time of Setting.
CCTS ISOLATED
24HR OM'T
CI
24Hr group omitted during the unset condition.
CCTS TESTED 01-38
TEST'D 01-38
Tc.01-38
The number of circuits tested during Walk Test.
CODE TAMPER
C.TMP 01-04
PT.01-04
Code tamper from keypad 01-04
COMMS ACTIVE
COM ACT
cA
Plug-on digicom active.
COMMS FAILED
COMS FLT
cF
Plug-on digicom failed to communicate.
COMMS SUCCESSFUL
COMS OK
cc
Plug-on digicom communicated successfully.
DATE CHANGED
DATE CHG
Dc
System Date changed.
DEFAULT CODE
DEFLT 01
DF
User passcode (01) reset to 5678 by the engineer.
DELAY ALARM 01-38
DELAY 01-38
AD.01-38
Delayed alarm during a part-set condition.
DURESS 01-15
DUR'SS 01-15
Du.01-15
Duress alarm from user passcode (01-15).
35

Other manuals for Menvier Security TS690

Related product manuals