4.2 Remote control commands
756/831 KF Coulometer, Instructions of Use
69
│
├ .ActualInfo Current data
│ ├ .Inputs I/O Inputs
│ │ ├ .Status Line status read only 4.2.2.69.
│ │ ├ .Change Change of line status read only ditto
│ │ ├ .Clear Clear change $G ditto
│ ├ .Outputs as for I/O Inputs
│ ├ .Assembly From Assembly
│ │ ├ .CyclNo Cycle number read only 4.2.2.70.
│ │ ├ .I Total charge (mA·s) read only ditto
│ │ ├ .Meas Measured indicator voltage read only ditto
│ │ ├ .Pot Voltage at generator electrode read only ditto
│ │ ├ .IPulse I of current pulse read only ditto
│ │ ├ .Bur Connected buret
│ │ │ ├ .V Volume of dosing unit read only ditto
│ │ │ ├ .Clear Clears counters above $G ditto
│ ├ .Titrator From Titrator
│ │ ├ .CyclNo Cycle number read only 4.2.2.71.
│ │ ├ .Water Mass of water read only ditto
│ │ ├ .Meas Measured indicator voltage read only ditto
│ │ ├ .dWaterdt Drift or rate read only ditto
│ │ ├ .I Total charge (mA·s) read only ditto
│ │ ├ .Pot Voltage at generator electrode read only ditto
│ │ ├ .IPulse I of current pulse read only ditto
│ ├ .MeasPt Entry in measuring point list
│ │ ├ .Index Index of entry read only 4.2.2.72.
│ │ ├ .X X coordinate read only ditto
│ │ ├ .Y Y coordinate read only ditto
│ │ ├ .Z1 Z1 coordinate read only ditto
│ │ ├ .Z2 Z2 coordinate read only ditto
│ ├ .EP EP entry
│ │ ├ .Index Index of entry read only ditto
│ │ ├ .X X coordinate read only ditto
│ │ ├ .Y Y coordinate read only ditto
│ ├ .Oven Oven data
│ │ ├ .HeatTime Heating time read only 4.2.2.73.
│ │ ├ .SampleTemp Sample temperature read only ditto
│ │ ├ .LowTemp Lowest temperature read only ditto
│ │ ├ .HighTemp Highest temperature read only ditto
│ │ ├ .GasFlow Gas flow read only ditto
│ │ ├ .UnitFlow Unit of gas flow read only ditto
│ ├ .Display Display
│ │ ├ .L1 Text line 1 up to 32 ASCII char 4.2.2.74.
│ │ ├ up to line 8
│ │ ├ .DelAll Delete display $G ditto
│ ├ .Comport Comport
│ │ ├ .Number COM where PC is connected read only 4.2.2.75.
│
├ .Assembly Assembly
│ ├ CycleTime Cycle time read only 4.2.2.76.
│ ├ ExV Volume of Exchange/Dosing unit read only ditto
│ ├ DeviceTemp Temperature of Coulometer read only ditto